<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-31 09-27-33
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.50 MHz 5/5, 61 dBuV Top51
Pilot RDS Phase Difference
6.2 kHz 3.0 kHz 0 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 69 kHz 19019 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,7 dBr 5,38 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" Top51 " 62B2 10 (Pop M) 1 0 1 5 9:27, 31.12.2024
RT
"TRAINING SEASON - DUA LIPA "
AF EON
95.5 MHz -
FM Scope Max at: 69 kHz MIN: 9 kHz % above 76 kHz: 0,0053 Acquired: 2024/12/31 9.26.30 Total samples: 19019 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: 6,3 dBr MIN: 4,7 dBr AVE: 5,38 dBr % above 12,2 dBr: 0,0 Last value: 4,7 dBr (2024/12/31 9.26.29) 09.12 09.14 09.16 09.18 09.20 09.22 09.24 09.26 0 2 4 6 Pm [dBr]